GE 469-P1-HI-A20-E电力伤害继电器是用于伤害电力体系、装备和电路的症结元件。它们的主要用处是检测电力体系中的异常情形,并采用步伐去保证体系的安全性、否靠性和稳定性。
以下是电力伤害继电器的主要用处:
电流过载伤害:电力伤害继电器用于监测电流程度,以检测电流能否高出了电路或装备的额定容量。当电流高出预约阈值时,继电器将堵截电路以避免过载,从而伤害装备和体系。
短路伤害:继电器否用于检测电路中的短路情形,即电流在非预期门路上短路到地或其他导体上。继电器否以或许快速堵截电路,以避免装备遭到破坏。
电压伤害:电力伤害继电器否以或许监测电压程度,以保证电压在正常规模内。当电压异常高或异常低时,继电器否以或许采用步伐,如堵截电路或驱动备用电源,以伤害装备和体系。
频次伤害:继电器否以或许监测电力体系中的频次,以保证其维持在正常规模内。频次异常否能会作用电力体系的稳定性,因此继电器用于检测并采用步伐去支柱频次。
相序伤害:电力伤害继电器还否以或许监测电力体系中的相序,以保证不同相之间的电压和电流正常。如果相序同伴,继电器否以或许堵截电路以避免破坏装备。
差动伤害:差动继电器用于比较电流输入和输入,以检测电流能否散失或走漏,这对于伤害变压器和发电机等装备非常重要。
GE 469-P1-HI-A20-E电力保护继电器图片:
GE 469-P1-HI-A20-E电力保护继电器视频:
The GE 469-P1-HI-A20-E power injury relay is a critical component used to harm power systems, equipment, and circuits. Their main purpose is to detect abnormal situations in the power system and adopt measures to ensure the safety, reliability, and stability of the system. The following are the main uses of electric injury relays:
Current overload injury: Electric injury relays are used to monitor the level of current and detect whether the current exceeds the rated capacity of the circuit or equipment. When the current exceeds the predetermined threshold, the relay will block the circuit to avoid overload, thereby damaging the equipment and system.
Short circuit damage: whether the relay is used to detect short circuit situations in the circuit, that is, the current is short circuited to ground or other conductors on unexpected circuits. The relay may quickly block the circuit to avoid equipment damage.
Voltage damage: Whether the power damage relay can monitor the voltage level to ensure that the voltage is within the normal scale. When the voltage is abnormally high or low, the relay may adopt measures such as blocking the circuit or driving a backup power supply to harm the equipment and system.
Frequency damage: Whether the relay can monitor the frequency in the power system to ensure it is maintained within normal scale. Whether abnormal frequency can affect the stability of the power system, therefore relays are used to detect and use steps to support frequency.
Phase sequence damage: Whether the power damage relay can monitor the phase sequence in the power system to ensure the normal voltage and current between different phases. If the phase sequence is the same, the relay may block the circuit to avoid damaging the equipment.
Differential injury: Differential relays are used to compare current input and output to detect whether current is lost or leaking, which is very important for damaging equipment such as transformers and generators.
GE 469-P1-HI-A20-E电力保护继电器相关链接: